Setup & Operation 12. I/O Remote Settings
RC90 (EPSON RC+ 7.0) Rev.8
61
(*1) “AutoMode output” ON is omitted from the table. This is an input acceptance condition for all
functions.
(*2) “Start input” executes Function specified by the following six bits: SelProg 1, 2, 4, 8, 16, and 32.
Function name
SelProg1
SelProg2
SelProg4
SelProg8
SelProg16
SelProg32
Main
0
0
0
0
0
0
Main1
1
0
0
0
0
0
Main2
0
1
0
0
0
0
Main3
1
1
0
0
0
0
.
.
.
Main60
0
0
1
1
1
1
Main61
1
0
1
1
1
1
Main62
0
1
1
1
1
1
Main63
1
1
1
1
1
1
0=OFF, 1=ON
(*3) “NoPause task” and “NoEmgAbort task” do not pause.
For details, refer to EPSON RC+ 7.0
Online Help
or
Pause
in
SPEL
+
Language Reference
.
(*4) Turns OFF the I/O output and initializes the robot parameter.
For details, refer to EPSON RC+ 7.0
Online Help
or
Reset
in
SPEL
+
Language Reference
.
(*5) The values specified by “SelRobot1, 2, 4, 8, and 16” correspond to the robot numbers.
Robot number
SelRobot1
SelRobot2
SelRobot4
SelRobot8
SelRobot16
0 (All)
0
0
0
0
0
1
1
0
0
0
0
2
0
1
0
0
0
3
1
1
0
0
0
.
.
.
13
1
0
1
1
0
14
0
1
1
1
0
15
1
1
1
1
0
16
0
0
0
0
1
0=OFF, 1=ON
(*6) Initializes the robot parameter.
For details, refer to EPSON RC+ 7.0
Online Help
or
Motor
in
SPEL
+
Language Reference
.
(*7) For details, refer to
EPSON RC+ 7.0
Online Help
or
MCal
in
SPEL
+
Language Reference
.
(*8) This is for experienced users only. Make sure that you fully understand the input specification before
using.
CmdRunning output and CmdError output will not change for this input.
“NoEmgAbort task” will not stop by this input.
When the input changes from ON to OFF, all tasks and commands will stop.
(*9) This function changes the output condition of MotorsOn, AtHome, PowerHigh, and MCalReqd.
By setting this signal with the condition selected using SelRobot1 - SelRobot16, you can switch the output
condition.
Once you select the condition, it will be kept until you change it or turn off / restart the Controller. All
manipulators are selected as default.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......