Setup & Operation 12. I/O Remote Settings
64
RC90 (EPSON RC+ 7.0) Rev.8
Name
Initial
Description
InsidePlane1
.
.
.
InsidePlane15
Not set
Turns ON when the robot is in the approach check plane.
For details, refer to EPSON RC+ 7.0
Online Help
or
Plane
in
SPEL
+
Language Reference
.
Alarm
Not set
Turns ON when any of the alarms is occurring.
Alarm1
Not set
Turns ON when a battery alarm of the controller is
occurring.
Alarm2
Not set
Turns ON when a battery alarm of the robot connected to
CU is occurring.
Alarm3
Not set
Turns ON when a grease alarm of the robot connected to CU
is occurring.
Alarm4
Not set
Turns ON when a battery alarm of the robot connected to
DU1 is occurring.
Alarm5
Not set
Turns ON when a grease alarm of the robot connected to
DU1 is occurring.
Alarm6
Not set
Turns ON when a battery alarm of the robot connected to
DU2 is occurring.
Alarm7
Not set
Turns ON when a grease alarm of the robot connected to
DU2 is occurring.
Alarm8
Not set
Turns ON when a battery alarm of the robot connected to
DU3 is occurring.
Alarm9
Not set
Turns ON when a grease alarm of the robot connected to
DU3 is occurring.
PositionX
Not set
Outputs current X coordinate in the World coordinate
system
(*6) (*7)
PositionY
Not set
Outputs current Y coordinate in the World coordinate
system
(*6) (*7)
PositionZ
Not set
Outputs current Z coordinate in the World coordinate system
(*6) (*7)
PositionU
Not set
Outputs current U coordinate in the World coordinate
system
(*6) (*7)
PositionV
Not set
Outputs current V coordinate in the World coordinate
system
(*6) (*7)
PositionW
Not set
Outputs current W coordinate in the World coordinate
system
(*6) (*7)
Torque1
Not set
Outputs the current torque value of Joint #1
(*6) (*7)
Torque2
Not set
Outputs the current torque value of Joint #2
(*6) (*7)
Torque3
Not set
Outputs the current torque value of Joint #3
(*6) (*7)
Torque4
Not set
Outputs the current torque value of Joint #4
(*6) (*7)
Torque5
Not set
Outputs the current torque value of Joint #5
(*6) (*7)
Torque6
Not set
Outputs the current torque value of Joint #6
(*6) (*7)
CPU
Not set
Outputs the CPU load factor of the user program
(*8)
ESTOP
Not set
Outputs how many times emergency stops have been
executed.
ALIVE
Not set
Output signal for alive monitoring of the controller. The
signal input by ALIVE input will be output. The master
equipment can perform alive monitoring of the controller
by switching the input periodically and checking the
output signal.
Summary of Contents for RC90
Page 1: ...Rev 8 EM158C3031F ROBOT CONTROLLER RC90 EPSON RC 7 0 ...
Page 2: ...ii ROBOT CONTROLLER RC90 EPSON RC 7 0 Rev 8 ...
Page 10: ...viii RC90 EPSON RC 7 0 Rev 8 ...
Page 17: ...Safety This section contains information for safety of the Robot System ...
Page 18: ......
Page 24: ......
Page 28: ...Setup Operation 1 Specifications 12 RC90 EPSON RC 7 0 Rev 8 1 3 Outer Dimensions Unit mm ...
Page 95: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Page 96: ......