21 REMOTE CONTROLLER (REMC)
S1C17001 TECHNICAL MANUAL
EPSON
283
0x5344: REMC Status Register (REMC_ST)
Register name Address
Bit
Name
Function
Setting
Init. R/W
Remarks
REMC
Status Register
(REMC_ST)
0x5344
(8 bits)
D7–1
–
reserved
–
–
–
0 when being read.
D0
REMDT
Transmit/receive data
1 1 (H)
0 0 (L)
0
R/W
D[7:1] Reserved
D0
REMDT: Transmit/Receive Data Bit
Sets the transmit data for data transmission. Receive data can be read when receiving data.
1 (R/W): 1 (H)
0 (R/W): 0 (L) (default)
If REMEN (D0/REMC_CFG register) is set to 1, the REMDT setting is modulated by the carrier signal
for data transmission and output from the REMO pin. For data receiving, this bit is set to the value cor-
responding to the signal level of the data pulse input.
Summary of Contents for S1C17001
Page 1: ...Technical Manual S1C17001 CMOS 16 BIT SINGLE CHIP MICROCONTROLLER ...
Page 33: ...4 POWER SUPPLY VOLTAGE 24 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 63: ...6 INITERRUPT CONTROLLER 54 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 87: ...8 CLOCK GENERATOR CLG 78 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 91: ...9 PRESCALER PSC 82 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 133: ...11 16 BIT TIMER T16 124 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 211: ...16 STOPWATCH TIMER SWT 202 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 219: ...17 WATCHDOG TIMER WDT 210 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 241: ...18 UART 232 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 277: ...20 I2 C 268 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...
Page 313: ...25 PACKAGE 304 EPSON S1C17001 TECHNICAL MANUAL This page intentionally left blank ...