7. Firmware
Update
S5U1C17001H2 User Manual
Seiko Epson Corporation
29
(ICDmini Ver2.0) (Rev2.0)
When S1C33 processor is selected
(gdb) target icd6 usb
C33 ICD33 debugging
Connecting with target ... done
CPU type and debug unit address setting ... done
Initializing ............... done
CPU cold resetting ......... done
Target connection test ..... omitted
ICD hardware version ... 2.0
ICD software version ... 1.5
Enables version information to be checked
CPU type and debug unit address setting ... done
CPU cold resetting ......... done
Boot address ............... xxxx
(6) Check the current firmware version, and enter the following commands if updating is required.
When S1C17 processor is selected
(gdb) c17 firmupdate
path\filename
.saf
When S1C33 processor is selected
(gdb) c33 firmupdate
path\filename
.saf
path
: Path for location of new firmware
filename
.saf: File name for new firmware
The process is complete when the following is displayed after the commands have been entered.
When S1C17 processor is selected
Erase flash data ...done
Load flash data ....done
ICD firmware update ...done
Please quit gdb, and power off ICD when LED2
/
LED3
/
LED4 is green.
(LED is green in the case of SVT17701).
When S1C33 processor is selected
Erase flash data ...done
Load flash data ....done
ICD firmware update ...done
Please quit gdb, and power off ICD when OK LED is on.
This procedure may take about 15 minutes.
While firmware updating is in progress, do not reset the S5U1C17001H or turn off the power.
Otherwise it may not be possible to restart the S5U1C17001H.
(7) Press the RESET/START switch. The LEDs illuminate or blink as shown below.
Firmware update successful
LEDs illuminate in sequence LED1
LED2
LED3
After which:
LED1
(blue) or
(green)
LED2
(green: successfully erased)
LED3
(green: successfully written or verified)
LED4
(green: firmware update successfully completed)