SC-F2000
Revision C
ADJUSTMENT
TF Adjustments
253
Confidential
[Blue]:
Button or menu name on the program screen /
[Black]:
Button or menu name on the operation panel of the printer
4.13.2 TF Belt Tension Adjustment
REQUIRED TOOLS
Sonic tensimeter U-507
MASS: 000.9
g/m
WIDTH: 025.0
mm/R
SPAN: 0998
mm
Any tools to flip the timing belt
EXECUTION MODE
Normal Mode
STANDARD VALUE
60 ± 3 N
PROCEDURE
1.
Remove the following part in advance.
Left Cover / Right Cover
2.
Turn the printer ON.
3.
Start the Service Program and select
[TF Belt Tension Adjustment]
.
4.
Click
[RUN]
.
The TABLE ASSY moves back and forth three times, then stops in the fully
retracted position.
5.
Input the following information on the belt into the tensimeter.
MASS:
000.9 g/m
WIDTH:
025.0 mm/R
SPAN:
0998 mm
6.
Bring the microphone of the tensimeter close to the belt as shown in
.
7.
Press the
[MEASURE]
button on the tensimeter, and flip the timing belt with
tweezers or a similar tool.
Figure 4-54. TF Belt Tension Adjustment
C H E C K
P O I N T
The distance between the microphone and the belt surface should
be 5 mm or less, but do not let it touch the belt.
C A U T I O N
Make sure to measure the tension of the upper belt. Otherwise,
the result may not be correct.
Flip the timing belt as weak as the tensimeter can measure it.
Be careful not to let the microphone touch the timing belt when
flipping the belt.
Measuring Microphone
TF Belt
Measure here under the
frame of the main body.
Summary of Contents for SC-F2000 Series
Page 1: ...SC F2000 Direct To Garment Printer SERVICE MANUAL SECP13002 Confidential ...
Page 10: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 29: ...Confidential C H A P T E R 2 TROUBLESHOOTING ...
Page 52: ...Confidential C H A P T E R 3 DISASSEMBLY ASSEMBLY ...
Page 192: ...Confidential C H A P T E R 4 ADJUSTMENT ...
Page 285: ...Confidential C H A P T E R 5 MAINTENANCE ...