SC-F2000
Revision C
DISASSEMBLY & ASSEMBLY
Disassembly and Assembly Procedure
91
Confidential
3.4.3.17 RIGHT IC COVER SENSOR
1.
Open the RIGHT IC COVER.
2.
Disengage the two hooks using flat-blade screwdriver or a similar tool, and
remove the RIGHT SENSOR COVER.
Figure 3-35. Removing the RIGHT SENSOR COVER
3.
Disengage the two hooks, and remove the RIGHT IC COVER SENSOR in the
direction of the arrow.
4.
Disconnect the cable from the connector of the sensor.
Figure 3-36. Removing the RIGHT IC COVER SENSOR
A D J U S T M E N T
R E Q U I R E D
When replacing/removing this part, refer to
Items and the Order by Repaired Part”
perform the specified operations including required adjustment.
RIGHT SENSOR COVER
Hooks
Engage the lower hook first when attaching the RIGHT IC
COVER SENSOR
).
Hooks
RIGHT IC COVER SENSOR
Cable
Connector
Side view
Hook (lower)
RIGHT IC COVER SENSOR