ADJUSTMENT
CR Related Adjustments
234
Confidential
8.
Press
[MEASURE]
on the tensimeter and flip the belt with tweezers or a similar
tool.
9.
Measure the belt tension for three times, and check if the average is within the
standards.
Within the standards: Go to
Out of the standards: Go to
10. Click
[Finish]
.
11. Turn the printer OFF to finish the adjustment.
Figure 4-15. Measuring the belt tension
C A U T I O N
Be sure to measure the tension of the belt on the upper side. If
you measure the tension of the belt on the lower side, the
measuring value may be inaccurate.
Flip the belt as weak as the tensimeter can measure it.
Be careful not to let the microphone touch the belt when
flipping the belt.
Upper timing belt
Measuring microphone
Center
(Measurement point)
CR Unit
Driven Pulley