SC-S30600 Series
Revision B
ADJUSTMENT
CR Related Adjustments
237
Confidential
6.
Since the APG is not switched correctly, execute the following remedy responding
to the symptom.
After taking the above measure, return to
7.
Click [Finish].
8.
Turn the printer OFF to finish the adjustment.
Symptom
Remedy
The CR Unit does not move to the APG
switch position (home position).
Since the CR Unit may not move smoothly,
lubricate the CR Unit.
The CR Unit moves to the APG switch
position but the APG mechanism does not
operate.
Since the APG Motor may not operate, check the
wiring of the APG Motor. If there is no trouble
for the wiring, replace the APG Motor.
The APG mechanism operates but the APG
is not switched correctly.
Since the APG mechanism on the CR Unit may
not have been installed correctly, replace the CR
Unit.