GX4 Manipulator 3. Environments and Installation
32
GX series Rev.2
3.3 Mounting Dimensions
The maximum space of the Manipulator is shown in the figure. The maximum space in each
figure includes an end effector radius of 60 mm. If the radius of the end effector exceeds 60
mm, define the radius as the distance to the outer edge of maximum space. If a camera or
electromagnetic valve extends outside of the arm, set the maximum range including the
space that they may reach.
Be sure to allow for the following extra spaces in addition to the space required for mounting
the Manipulator, Controller, and peripheral equipment.
Space for teaching
Space for maintenance and inspection
Space for cables
The minimum bend radius of the power cable is 60 mm. When installing the cable, be sure
to maintain sufficient distance from obstacles. In addition, leave enough space for other
cables so that they are not bent forcibly.
Ensure distance to the safeguard from the maximum motion range is more than 100 mm.