Maintenance 4.5 DPB (Drive Unit)
135
LED
LED No.
Function
LED1
1
The number “1” indicates that an unresettable error relating
to motor control with/in any of the robot axes occurs.
LED2
2
The number “2” indicates that a resettable error relating to
motor control with/in any of the robot axes occurs.
LED3
ERROR
Lights when the CPU of the Drive Unit detects an error.
LED4
RUN
Lights while the CPU of the Drive Unit is operating
normally.
LED5
E-STOP
Lights when in the emergency stop condition.
LED6
MOTOR
POWER
Lights when the motor power is ON.
(Motor Power: The DC power supply that inputs to the
Motor Driver module to drive the motor. This DC power is
generated by regulating AC200V or the local equivalent
power.)
LED7
POWER
Lights when the Drive Unit is turned ON.
LED8
This lamp turns OFF when the +24V voltage drops.
LED9
This lamp indicates the charge status of the condenser.
Summary of Contents for SRC520
Page 1: ...SRC520 Rev 4 EM015C868F ROBOT CONTROLLER ...
Page 2: ...ROBOT CONTROLLER SRC520 Rev 4 ...
Page 13: ...Function The manual herein explains in detail the functions of the robot controller SRC520 ...
Page 14: ...Function 2 ...
Page 29: ...Function 2 3 Control Unit Part Names and Functions 17 2 3 4 Dimensions mm ...
Page 35: ...Function 2 4 Drive Unit Part Names and Functions 23 2 4 5 Dimensions mm ...
Page 36: ...Function 2 4 Drive Unit Part Names and Functions 24 ...
Page 50: ...Function 3 5 Noise Countermeasures Installation 38 ...
Page 66: ...Function 6 3 Pin Assignments D I O Connector 54 ...
Page 96: ...Function 9 2 Preparation for Communication RS 232C Settings 84 ...
Page 106: ...Function 11 Stand alone Option for SRC520 94 ...
Page 108: ...Maintenance 96 ...
Page 139: ...Maintenance 4 3 Drive Unit Drive Unit 127 4 3 Drive Unit 4 3 1 System Configuration ...