EPSON Stylus CX3100/3200
Revision A
Disassembly and Assembly
Scanner Unit Disassembly
41
4.3.2 Upper Housing Removal
1.
Remove the scanner unit. (Refer to
“Scanner Unit Removal” on page 38
2.
Remove the hinge. (See
)
3.
Remove the two screws (CCP-Tite 3x8 F/Zb) securing the upper housing to the
scanner unit.
NOTE:
Screw tightening torque: TBD
Figure 4-9. Screws securing the Upper Housing
4.
Disengage the two hooks fastening the upper housing and lower housing.
Figure 4-10. Hook Position
5.
Open the upper housing by lifting it from the rear.
6.
Insert your hand through the opening and disconnect the harness for the panel from the
connector on the panel circuit board.
Figure 4-11. Harness Disconnection