EPSON Stylus CX3100/3200
Revision A
Disassembly and Assembly
Scanner Unit Disassembly
42
4.3.3 Motor Unit Removal
1.
Remove the scanner unit. (Refer to
“Scanner Unit Removal” on page 38
2.
Remove the hinge. (See
)
3.
Remove the upper housing. (See
“Upper Housing Removal” on page 41
)
4.
Disconnect the motor harness from the lower housing.
Figure 4-12. Motor Harness
5.
Loosen the timing belt by pushing the driven pulley and remove the timing belt.
Figure 4-13. Driven Pulley for Timing Belt
6.
Remove the three screws (CCP-Tite 3x8 F/Zb) securing the motor bracket to the lower
housing.
NOTE:
Screw tightening torque: TBD
Figure 4-14. Screws securing the Motor Unit
7.
Remove the motor unit.
C A U T I O N
Lead the harness of the motor along the groove in the lower
housing without floating.
CCP-Tite 3x8F/Zn
Summary of Contents for Stylus CX3100
Page 1: ...EPSON StylusCX3100 3200 Scanner Printer Copier SERVICE MANUAL SEOT02002 ...
Page 5: ...Revision Status Revision Issued Date Description A Augusut 1 2002 First Release ...
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 13: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 17: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 34: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 57: ...C H A P T E R 5 ADJUSTMENT ...
Page 74: ...C H A P T E R 6 MAINTENANCE ...
Page 80: ...C H A P T E R 7 APPENDIX ...
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ...EPSON Stylus CX3100 3200 Revision A Appendix Exploded Diagrams 88 7 4 Exploded Diagrams ...
Page 90: ...EPSON Stylus CX3100 3200 Revision A Appendix ASP List 89 7 5 ASP List ...