EPSON Stylus Pro 10000/10000CF
Revision A
Disassembly & assembly
Disassembly Flow
185
4.2.3.26 Removing the P_THICK Sensor
1.
Remove the H Top Cover as described in “H Top Cover Removal 123.
2.
Push the paper hold lever to the front. (Unlock condition)
Figure 4-172.
3.
Marking the P_THICK sensor bracket position on the CR guide rail.
Figure 4-173.
4.
Remove two screws (M3x6) fixing the P_THICK sensor.
Figure 4-174.
5.
Disconnect the cable connector from the P_THICK Sensor.
Figure 4-175.
Paper hold lever
P_THICK sensor
Marking
CR guide rail
P_THICK sensor
Screw
Cable connector