EPSON Stylus Pro 10000/10000CF
Revision B
Adjustment
Adjustment Steps
191
5.2 Adjustment Steps
This section describes the detailed steps for performing the adjustment procedures listed in
Table 5-2.
5.2.1 Parameter Backup
The C362Main Board contains NVRAM (Flash-ROM & EEPROM) which is used to store
the parameter information and firmware commands that control the printer. This parameter
includes "Panel setting value", "Exclusive parameters for C362Main board (Unerasable)"
and "Mechanism adjustment value".
When exchange the C362MAIN board, you can maintain the matching with current printer
mechanism and eliminate several adjustment operations with backup of the "panel setting
value" and mechanism adjustment value that are stored in the previous C362MAIN board
and restore them to the new one.
Backup operations: Uploads the backup parameter (data) that is stored in the flash memory
of current C362MAIN board, then write to the flash memory card on the new C362MAIN
board.
REQUIREMENTS FOR PARAMETER BACKUP
o
#F727 Flash Memory Card (1050073))
(Conforms to PCMCIA Rel 2.1/JEIDA Ver 4.2 (Type II) / 5V Read/Write
operation)
Part # 1050073 (Fujitsu: MB98A81183-15)
o
Memory card writing utility
(i.e. Adtech CardUT97)
o
PC with memory card writer or stand alone memory card writer
o
IPL contained in the following directory in the service manual data disk.
Folder: \Prog\Ipl\
File: *******.ROM
Before backing up the parameters to the PC card, the above file must be written to
the Flash Memory Card using the card writing utility:
C H E C K
P O I N T
If you can backup the parameters correctly, replace the main board
and upload the parameters into the new board. A part of the
adjustment that used self-diagnostic function becomes unnecessary. In
this case, take the next procedure.
1.
Back up the parameters as described in “Parameter Backup” on
page 191.
2.
Replace the C362Main board as described in chapter 4.
3.
Down load the parameters as described in “Parameter Backup”
on page 191.
4.
Upload the firmware as described in “Firmware Upload” on
page 193.
5.
Perform the paper-related sensor adjustment.
C A U T I O N
The backup card you use in these steps only works with the Stylus Pro
10000/10000CF; do not attempt to use it with other printers.
Do not use the backup card for the others. The programs vary and
using the wrong program may cause a wide variety of problems
depending on which parameter(s) are written incorrectly.
Summary of Contents for Stylus Pro 10000 Series
Page 7: ...Revision Status ...
Page 8: ...Revision Issued Date Description Rev A March 30 2001 First Release ...
Page 13: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 59: ...EPSON Stylus Pro 10000 10000CF Revision B Product Description Jumper Settings 59 ...
Page 60: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 86: ...C H A P T E R TROUBLESHOOTING ...
Page 113: ...C H A P T E R DISASSEMBLY ASSEMBLY ...
Page 187: ...C H A P T E R ADJUSTMENT ...
Page 276: ...C H A P T E R MAINTENANCE ...
Page 289: ...C H A P T E R APPENDIX ...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ......