EPSON Stylus Pro 10000/10000CF
Revision B
Adjustment
Self-Diagnostics
267
5.3.8.2 PF Motor
Perform the PF motor reliability test.
The motor is actuated designated number.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the PF motor reliability test menu sequence.
Figure 5-99.
o
The maximum value of the paper feed is [100.0mm].
o
The maximum value of the reliability number designation is [99,999,999 times].
o
When the [Pause] key is pushed during the reliability test, the test can be broken.
Table 5-22.
Movement distance is less
than 8.6mm
Movement distance is more
than 8.6mm
Speed
25 CPS
52 CPS
Acceleration speed
0.1G
0.2G
Decrease speed
0.1G
0.2G
Enter
Enter
Enter
Feed Amount : 0.1mm
Life Count : -1
Count :10
End : 50
Adjustable with "Paper Feed +/-" key
at unit of 0.1mm.
Adjustable with "Paper Feed +/-" key.
Summary of Contents for Stylus Pro 10000 Series
Page 7: ...Revision Status ...
Page 8: ...Revision Issued Date Description Rev A March 30 2001 First Release ...
Page 13: ...C H A P T E R PRODUCTDESCRIPTION ...
Page 59: ...EPSON Stylus Pro 10000 10000CF Revision B Product Description Jumper Settings 59 ...
Page 60: ...C H A P T E R OPERATINGPRINCIPLES ...
Page 86: ...C H A P T E R TROUBLESHOOTING ...
Page 113: ...C H A P T E R DISASSEMBLY ASSEMBLY ...
Page 187: ...C H A P T E R ADJUSTMENT ...
Page 276: ...C H A P T E R MAINTENANCE ...
Page 289: ...C H A P T E R APPENDIX ...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ......