EPSON Stylus Pro 4400/4450/4800/4880/4880C
Revision C
Disassembly & Assembly
Disassembly Procedures
277
4.2.7.6 Multi Sensor
1.
2.
Move "Carriage Unit" to center of printer.
(Refer to "4.2.4.3 C593_SUB Board" (p234).)
3.
Remove the two screws securing "Multi Sensor" to the "Carriage Unit".
C.B. (P2) 3x6:
2 pcs.
4.
While holding the "Multi Sensor" so as not to drop, and move the "Carriage
Unit" to the left end of the printer keeping clear of the platen.
5.
Remove the "Multi Sensor" from the "Carriage Unit" in the downward
direction.
6.
Disconnect the connector connected to the "Multi Sensor" and remove the
"Multi Sensor".
Figure 4-93. Screws Securing Multi Sensor
Figure 4-94. Multi Sensor Removal
Figure 4-95. Connecting Status of Multi Sensor Connector
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5
and
perform specified adjustments after replacing or installing a
"Multi Sensor".
C.B. (P2) 3x6
Connector