5.
Loosen the "Coupling Screw, M7"s that secure the "Tube, Supply, Ink"s to
the "Head Unit" to draw out the "Coupling Screw, M7"s.
6.
Remove the "O-ring, Coupling M7"s and "Coupling Screw, M7"s from the
"Tube, Supply, Ink"s.
(Refer to "4.2.8.2 Valve Assy., Head" (p291).)
7.
Remove the five "Holder, FFC"s ("Holder, FFC; B").
8.
9.
Remove the "Ink Tube Unit" from the "Carriage Unit".
(Refer to "4.2.7.1 Carriage Unit" (p266).)
10. Remove the screw that secures both the "Holder, Tube, A" and "Holder,
Tube, B", and separate the "Holder, Tube, A" from the "Holder, Tube, B".
C.B.P. 3x8:
1 pc.
Figure 4-185. Coupling Screw, M7 Removal
Figure 4-186. Separation Holder, Tube, A from Holder, Tube, B