EPSON Stylus Pro 4400/4450/4800/4880/4880C
Revision C
Disassembly & Assembly
Disassembly Procedures
343
4.2.9 Paper Feed Mechanism
4.2.9.1 Release Unit
1.
2.
Remove the screw securing "Cover, Inner, Release".
C.B.S. 3x8:
1 pc.
3.
Slide "Cover, Inner, Release" to right side, free the two ribs and remove it
upward.
4.
Remove the two screws securing "Plate, P Cover, Right" and remove
"Plate, P Cover, Right".
C.B.S. 3x6:
2 pcs.
Figure 4-197. Cover, Inner, Release Removal
Figure 4-198. Plate, P Cover, Right Removal
.
Align "Plate, P Cover, Right" dowel with main frame
positioning hole.
Dowel
Positioning Hole
Cover, Inner, Release
Ribs
C.B.S. 3x8
Plate, P Cover, Right
C.B.S. 3x6