EPSON Stylus Pro 4400/4450/4800/4880/4880C
Revision C
Disassembly & Assembly
Disassembly Procedures
351
4.2.9.4 P_THICK Sensor (0.8) / P_THICK Sensor (0.3)
1.
2.
Remove "PT Sensor Unit".
(Refer to "4.2.9.1 Release Unit" (p343).)
3.
Disconnect connectors from "P_THICK Sensors".
4.
Release the three tabs securing "P_THICK Sensor", and remove the
"P_THICK Sensors".
Figure 4-212. P_THICK Sensors Removal
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5
and
perform specified adjustments after replacing or installing a
"P_THICK Sensor".
Tabs
Connector
Connector
P_THICK Sensor (0.8)
P_THICK Sensor (0.3)