3.6.1 Specifications
Ensure that the available power meets following specifications.
Item
Specification
Voltage
100 to 240 VAC
(Input voltage should be with in
±
10
%
of the rated voltage.)
Phase
Single phase
Frequency
50/60 Hz
Momentary Power Interrupt Less than 10 msec.
Rated Capacity
T3-B: 660 VA
T6-B: 1,200VA
Short-circuit
Current Rating
5kA
Maximum Load Current
T3-B: 3.3A
T6-B: 6.0A
Peak Current
(When AC power is turned ON)
T3-B: Max. 30A (2 ms or less)
T6-B: Max. 60A (2 ms or less)
Leakage Current
Max. 10 mA
Ground Resistance
TN ground (100
Ω
or less)
Summary of Contents for T-B Series
Page 1: ...SCARA ROBOT T B series MANUAL Rev 1 EM217R4788F ...
Page 2: ...SCARA Robots T B series Manual Rev 1 ...
Page 16: ...TABLE OF CONTENTS xiv T B series Rev 1 ...
Page 18: ......
Page 40: ...Installation 5 Second Step 24 T B series Rev 1 ...
Page 42: ......
Page 58: ...T3 B T6 B Manipulator 2 Specifications 42 T B series Rev 1 2 3 Outer Dimensions 2 3 1 T3 B ...
Page 59: ...T3 B T6 B Manipulator 2 Specifications T B series Rev 1 43 2 3 2 T6 B ...
Page 77: ...T3 B T6 B Manipulator 3 Environments and Installation T B series Rev 1 61 T6 B A B ...
Page 158: ...T3 B T6 B Manipulator 18 Error Code List 142 T B series Rev 1 ...
Page 160: ......
Page 168: ......
Page 178: ...Appendix B Time and Distance of Free Running in Emergency 162 T B series Rev 1 ...
Page 182: ...Appendix C Time and Distance of Free Running When Safeguard Is Opened 166 T B series Rev 1 ...