Confidential
18
SHEET
App. 18
NO.
SHEET
REVISION
F
TITLE
NEXT
App. 19
TM-T90
Specification
(STANDARD)
Command TM-T90
original
TM-T88II-compatible
mode
(Msw 8-7 On)
TM-T88II
GS ( K
Newly added.
Default of times of a
head division is 2.
GS ( L
Newly added.
←
GS ( M
Newly added.
Default value can be customized.
←
Executes a group of
customizing commands in the
initialization and sets a default
value.
GS ( N
Newly added.
←
--
GS ( k
Newly added.
←
--
GS
∗
User-defined characters and
user-defined bit-images can be
defined simultaneously (the size is
the same as before).
→
User-defined characters and
user-defined bit-images
cannot be defined simulta-
neously. When the command
is executed, the definition of
any user-defined bit- image is
cleared.
GS
I
After changing printer ID, the printer
name was changed. The status of
DIP switches transmitted by n = 112
or n = 113.
Product ID: 32
Version ID: 70
GS T
Newly added.
←
GS V
Add the range, n = 0, 48, 65. This
change relates to the printer
specification and the function has not
been changed.
Range:
➀
0
≤
n
≤
5, 48
≤
m
≤
49
➁
65
≤
m
≤
66, 0
≤
n
≤
255
←
Range:
➀
m = 1, 49
➁
m = 66, 0
≤
n
≤
255
GS W
[Default] n
L
= 0, n
H
= 2
<When paper width is 60 mm>
n
L
= 128, n
H
= 1
←
[Default] n
L
= 0, n
H
= 2
<When paper width is 58 mm>
n
L
= 104, n
H
= 1
GS a
Panel switch status is added to the
ASB status
➁
The following bits are added to the
second byte (printer information):
Bit 0: Not waiting for online
recovery/waiting for online
recovery
The ASB for the panel
switch status is always
disabled (cannot be
set).
In the
TM-T88II-compatible
mode, since a cover
open error during
printing is an automatic
recovery error, the
second bit of the
second byte is always
0.
➁
The second byte (printer
information)
Bit 0: Undefined
Bit 1: Undefined.
Bit 2: Undefined.