Precautions

CAUTIONS:

Disconnect the power supply from the printer before you remove the 
UB-S01; otherwise you may damage the UB-S01 and the printer. You 
must disconnect the power supply because the electrical current is 
flowing in some parts of the printer circuit even when the power switch 
is turned off.

Wear a grounded wrist strap when handling the UB-S01 to prevent 
damage from static electricity.

To avoid contamination, do not touch the board connector.

Unpacking

Make sure you have these items:

UB-S01

This manual

Procedure

1.

Remove the two screws that securing the UB-BOARD; then pull the UB-
BOARD to remove it.

CAUTION:

Put the UB-BOARD into an anti-static bag for storage to prevent 
damage from static electricity.

2.

Hold the UB-S01 as shown in the illustration below. Push the UB-S01 in 
gently until you feel the connector fit into place.

3.

Secure the UB-S01 with the two screws.

4.

Change the printer DIP switches to match the printer to the new interface.
See the printer documentation for information about these settings.

Make sure you set the printer DIP switches. Otherwise the printer may 
not work correctly.

Connector of the UB-S01

Connector of the TM printer

Summary of Contents for UB-S01

Page 1: ... which this board is installed becomes class A devices The connection of a non shielded printer interface cable to the board will invalidate the EMC standards of this device You are cautioned that changes or modifications not expressly approved by Seiko Epson Corporation could void your authority to operate the equipment FCC Compliance Statement For American Users This equipment has been tested an...

Page 2: ... have these items UB S01 This manual Procedure 1 Remove the two screws that securing the UB BOARD then pull the UB BOARD to remove it CAUTION Put the UB BOARD into an anti static bag for storage to prevent damage from static electricity 2 Hold the UB S01 as shown in the illustration below Push the UB S01 in gently until you feel the connector fit into place 3 Secure the UB S01 with the two screws ...

Page 3: ...よび物的損害のみの発生が想定される内容を示しています 電波障害自主規制について 注意 この装置は クラス A 情報技術装置です この装置を家庭環境で使用すると 電波妨害を引き起こすことがあります この場合には使用者が適切な対策を講ずるよう要求されることがあります VCCI A 交換作業上の注意 注意 作業の前にプリンターから電源を取り外してください 電源スイッチをオフ にするだけでなく 電源を取り外してください プリンターの電源スイッチをオフにしても 内部の回路基板には通電してい るところがあります 電源を取り付けたまま交換作業を行うと UB S01 およびプリンターが故障する可能性があります 作業中は接地されたリストバンドを装着してください リストバンドを装着 せずに作業をすると 静電気による故障の原因になります UB S01 のコネクターを手で触れないでください 汚れによる動作不良を起...

Page 4: ...D は 静電気による故障を防ぐため 静電防止処理を した袋などに保管してください 2 図のように UB S01 のコネクターをプリンターのコネクターに合わせま す UB S01 を押して コネクターを接続してください 3 2 つのネジで UB S01 を固定します 4 新しいインターフェイスに合わせて プリンターのディップスイッチを 変更します ディップスイッチの説明については プリンターのマニュアルを参照し てください ディップスイッチの設定は必ず行ってください プリンターが正しく動 作しないことがあります UB S01 のコネクター TM プリンターのコネクター ...

Reviews: