background image

Setup Guide

 Connect the emergency stop connector to the 
EMERGENCY port on the robot’s interface panel. 

 Connect the USB cable to the 

PC port on the robot’s 

interface panel.

EMERGENC

Y

RESET

POWE

R

MEMOR

Y

PROGRA

M

AUTO

TEACH

ESTO

P

ERRO

R

TEST

STATUS

MODE

PC

LAN

OPTIO

N

I/O-OUT

I/O-IN

AC 110V

-240V

5

  Attaching a Power Adapter 

and Turning on the Robot

The power cable is already attached to the robot’s power 
supply. You must attach a power adapter plug to the other 
end of the power cable. See the example power adapter plugs 
below:

220 V

110 V

Warning:

 Wire the power cable only to a power adapter plug; never 

wire the power cable directly to a power panel or other hard-wired 
power supply. You must be able to unplug the cable from a power 
outlet for safe operation.

Make sure the power line includes a two-pole, disconnect 
type, ground leakage circuit breaker or a circuit breaker in the 
AC power cable line with a rated current of 20 A or less. 

For wiring details and information on the robot’s power supply, 
see the online Epson Robot Manual.

Caution:

 The robot does not have a power switch; once you plug it 

into a power outlet, the robot’s power is on.

 Attach a grounding wire with a core size of 5.5 mm

2

 or 

larger to the bolt hole shown here.

Warning:

 Improperly connecting the ground wire may cause a 

fire or electric shock.

IMPORTANT: Before using this product, make sure you read these 
instructions, and the safety instructions and guidelines in the online Epson 
Safety and Installation Manual
.

1

 Unpacking the Robot

 Remove the robot and optional equipment from the 
packing container.

 Set aside these parts for use later:

Emergency stop

Optional emergency 

stop connector

USB cable

Epson

®

 RC+ 7.0 DVD

 Remove all the packaging materials from the robot. 

Caution:

 Do not remove the TP Bypass Plug from the interface 

panel or the robot cannot operate.

EMERGENCY

RESET

POWER

MEMOR

Y

PC

LAN

OPTIO

N

I/O-OUT

I/O-IN

AC 110V

-240V

TP

Bypass

Plug

2

 Installing the Software 

 (Windows

®

 Only)

 Insert the Epson RC+ 7.0 DVD into a DVD drive on the 
computer you will use to program the robot. 

Note:

 You can download manuals for your product from the 

Epson website. Visit 

www.epsonrobots.com/product-manuals 

and search for your product. If you need to download the Epson 
RC+ 7.0 software, send an email request to 

applications@

robots.epson.com to receive a download link.

 Follow the on-screen instructions to install the software. 

 Double-click  the 

EPSON RC+ 7.0 icon on your desktop to 

start the Epson RC+ 7.0 software. 

See the online Epson Safety and Installation Manual for details 
on installing and using the Epson RC+ 7.0 software.

3

  Mounting the Robot to Your 

Work Surface

Before you begin, make sure your work area and the surface on 
which you will install the robot meet the requirements listed in 
the Epson Robot Manual.

You need the following hardware (not included) to mount the 
robot to your work surface:

•  4 M8×35 bolts
•  4 spring washers
•  4 flat washers

X4

X4

X4

Note:

 The bolts must conform to ISO898-1 Property Class 10.9 or 

12.9.

 Place the robot on your work surface.

Caution:

 The robot cannot stand on its own. Be sure to properly 

hold and support the robot during the mounting process.

 Trace the location of the mounting holes onto your work 
surface so you can tap M8 holes, if you have not already. 
For details on work surface and hole requirements, see 
the online Epson Robot Manual.

 Align the mounting holes with the holes in your work 
surface and secure the robot using the four M8×35 bolts.

Spring washer

M8x35

Flat washer

0.67 inch (17 mm)

Screw hole 

(0.71 inch [18 mm] 

or more depth)

Note:

 Tighten the bolts to a torque of 32.0+/-1.6 N-m.

4

  Connecting the USB Cable  

and Emergency Stop

Caution:

 Do not attach the power adapter or attempt to plug in the 

robot now; connect the USB cable and emergency stop first.

You can install the emergency stop that came with the robot 
or install your own emergency stop that meets the safety 
requirements listed in the online Epson Robot Manual.

 To connect an emergency stop, first do one of the 
following: 

•  If you are installing the emergency stop included with 

the robot, rotate the stop button counterclockwise to 
release the button, or the robot cannot operate.

•  If you are installing your own emergency stop, wire it to 

the 25-pin D-Sub connector that came with your robot. 
Be sure to use the clamshell and strain relief during 
assembly. For wiring details, see the online Epson 
Robot Manual
.

VT6L
All-in-One 6-Axis Robot

Summary of Contents for VT6L

Page 1: ... from the Epson website Visit www epsonrobots com product manuals and search for your product If you need to download the Epson RC 7 0 software send an email request to applications robots epson com to receive a download link 2 Follow the on screen instructions to install the software 3 Double click the EPSON RC 7 0 icon on your desktop to start the Epson RC 7 0 software See the online Epson Safet...

Page 2: ... from the Epson website Visit www epsonrobots com product manuals and search for your product If you need to download the Epson RC 7 0 software send an email request to applications robots epson com to receive a download link 2 Follow the on screen instructions to install the software 3 Double click the EPSON RC 7 0 icon on your desktop to start the Epson RC 7 0 software See the online Epson Safet...

Page 3: ...day through Friday Training To help you get the most from your Epson product Epson offers programming maintenance and vision classes Visit www epsonrobots com training for more information 2 Plug the robot s power cable into a power outlet The lights on the back of the robot flash for about 30 seconds as the robot initializes EMERGENCY POWER TP Bypass Plug RESET MEMORY PROGRAM AUTO TEACH TEST MODE...

Page 4: ...day through Friday Training To help you get the most from your Epson product Epson offers programming maintenance and vision classes Visit www epsonrobots com training for more information 2 Plug the robot s power cable into a power outlet The lights on the back of the robot flash for about 30 seconds as the robot initializes EMERGENCY POWER TP Bypass Plug RESET MEMORY PROGRAM AUTO TEACH TEST MODE...

Reviews: