-27-
12. MALFUNCTION AND REMEDIES
Gli inconvenienti di funzionamento che si riscontrano negli apparecchi frigoriferi sono dovuti, nella maggioranza dei
casi ad installazione elettrica difettosa. Si tratta quindi di cause che possono essere facilmente eliminate sul posto.
THE UNIT DOES NOT START
CAUSE
SOLUTION
AUTHORISED STAFF
Check that the unit is properly plugged
Insert the plug
User
Check that the unit is properly plugged
Insert the plug correctly
User
Check that the plug cord is broken
Replace the plug cable
Technical support
If power failure is not due to any of the above causes, call the nearest after-sales service immediately,
empty the cabinet and store the foods in coldrooms or refrigerators that may ensure their preservation
temperature.
THE INTERNAL TEMPERATURE IS NOT COLD ENOUGH
CAUSE
SOLUTION
AUTHORISED STAFF
Check door is perfectly closed
Close correctly
User
Make sure that the cabinet has been filled correctly
Load the product correctly
User
Check that the unit is not adjacent to sources of heat
Position the equipment correctly
User
Check that the air can properly circulate.
Position the equipment correctly
User
Check the temperature setting
Set the correct temperature
Technical support
Check that there is not too much ice on the evaporator
Defrost the equipment
User
If failure to cool should is not due to any of the above reasons it it persists on even after the above checks, resort to
the nearest after-sales service.
L’APPARECCHIO È RUMOROSO
CAUSE
SOLUTION
AUTHORISED STAFF
Check that all the bolts and nuts are properly fastened
Screw in the screws
User
Check that the unit is placed on an even surface
Position the equipment correctly
User
Check if any pipe or fan is in contact with any other part of the body
Switch off the counter and distance
the parts in contact in the event
the problem persists, contact the
support service.
Technical support
Should the inconvenience persist, contact the nearest after-sales service.
13.
WIRING DIAGRAM
13.1
WIRING DIAGRAMS LEGEND
REF
DEVICE
CE
ELECTRONIC CONTROL
CO
COMPRESSOR
CS
PLUG CABLE
LDV
TANK INNER LED LIGHT
LPS
LED POWER SUPPLY UNIT
MI
INNER MOTORISED FAN
MPS
MOTOR FAN POWER SUPPLY UNIT
PBD
DEFROST END PROBE
PR
POWER SOCKET
RPS
RESISTOR POWER SUPPLY UNIT
RT
DOOR RESISTOR
SP
POWER PLUG
Summary of Contents for iarp Cool Emotions EXCITE
Page 2: ...2...
Page 15: ...15 13 2 SCHEMA ELETTRICO EXCITE...
Page 28: ...28 13 2 EXCITE WIRING DIAGRAM...
Page 41: ...41 13 2 L GENDE SCH MAS EXCITE...
Page 54: ...54 13 2 SCHALTPLAN EXCITE...