-18-
TANK CLEANING
For cleaning operation of the tank proceed as follows:
1) Remove the product from the tank.
2) Switch off the unit using main switch (see control panel) and unplug the unit.
3) Before cleaning the tank the inside temperature must be the same as the ambient.
4) Clean the tank; don’t use too much water that could damage the motor fans; rinse and dry carefully.
5) Turn the unit on, with the night curtain (if present) lowered and 1 hour later you can load the product again.
Warning! Do not use water jets for cleaning: this can damage the electrical
parts.
Warning! Do not use mechanical appliances or other means to speed up the
defrosting process, other than those recommended by the manufacturer.
GEMMA 30
SAFETY THERMOSTAT
RESET BUTTON
AUTOMATIC DEFROSTING
APPLIANCES USING R404a COOLING FLUID
On theese appliances
the defrosting is automatic
.During the defrosting period, the resulting water
is collected into a stainless stell tray and dispelled by an automatic electrical evaporating system. In
case of fault the security thermostat breaks the voltage to the electrical resistance, and the water brims
on the floor;
call the operator
, who must reset the thermostat stud only after having eliminate the
cause of the fault.
IF THE HEATER DON'T WORK PLEASE
VERIFY AND REPAIR THE SAFETY
THERMOSTAT SWITCH LAYING
SI LA RESISTANCE NE FUNCTION PAS
VERIFIER ET RETABLIR LE POUSSOIR
DU THERMOSTAT DE SECURITE
SICUREZZA PREMENDO IL PULSANTE
RIPRISTINARE IL TERMOSTATO DI
DELLA RESISTENZA VERIFICARE E
IN CASO DI MANCATO FUNZIONAMENTO
WARNING
ATTENTION
ATTENZIONE
Warning!
Check and clean periodically the tray sucking any dirt and/or remnants with a properly powerful
aspirator suitable for liquids.
GEMMA 60
SAFETY THERMOSTAT
RESET BUTTON
SAFETY THERMOSTAT
RESET BUTTON
GEMMA 120 - 180