QuadroFXO Manual II: Administrator's Guide
Quadro's Graphical Interface
QuadroFXO; SW Version 5.1.x
52
The Route incoming FXO Call to manipulation radio buttons
group allows you to define the destination where incoming calls
addressed to the corresponding FXO line will be forwarded to.
•
Extension – this selection allows you to choose the local
PBX user or auto attendant extension to forward calls. If an
inactive extension is chosen from this list, the voice mail
system will answer the call addressed to the corresponding
FXO line. If the Auto Attendant extension is chosen, it will
become the “default user” for the corresponding FXO line
on the Quadro.
•
Routing – this selection allows you to forward the incoming
calls to the destination defined through
selection requires you to enter a routing pattern to the
corresponding field. Based on the registered PSTN users,
the caller will be able to reach the destination according to
configurations in Call Routing Table.
By choosing a destination, the Quadro administrator virtually
assigns a default number that will start ringing when a call is
initiated to the Quadro’s PSTN number.
Fig. II-95: FXO Line Settings page
The PSTN Number text field allows you to enter the PSTN number that the current FXO line is attached to. The field value is optional and used as
an identification parameter for FXO lines. The field value can be left empty.
Alternative AC Termination Mode appears if the local country (Germany, Israel, France, etc.) selected for Quadro has two COs that use different
types of AC termination. Contact your CO to learn about your AC termination mode. Selecting the checkbox may help if the voice quality over FXO is
poor or an echo is noticed.
To modify the FXO Settings
1.
Select the FXO line number from the FXO Settings table. The FXO Settings -FXO# will appear where the line settings may be modified.
2.
Enable the FXO line to receive calls from PSTN. To reject calls from/to the PSTN deselect the Enable FXO checkbox.
3.
If FXO has been enabled, select the Call Type from the Allowed Call Type drop down list and the extension from the Route FXO Call to drop
down list to route the FXO calls correspondingly.
4.
Insert a PSTN number in the same named text field to identify the FXO line.
5.
Enable Alternative AC Termination Mode if your CO so requires.
6.
Press Save to submit the FXO line settings.
PSTN Lines Sharing
PSTN Lines Sharing page is used to configure QuadroFXO to act as an FXO expansion device for the remote Quadro IP PBX, i.e. to share its FXO
lines to the master Quadro IP PBX. This provides Quadro IP PBX a possibility to call not only through local FXO lines but also through available
shared FXO lines on the QuadroFXO.
When PSTN Lines Sharing is enabled, FXO Settings page becomes read-only on QuadroFXO and corresponding routing patterns are automatically
created in the
table. Also following dependencies are applicable:
•
Information defined in PSTN Number text field, as well as the configured Allowed Call Types for each of the FXO lines on the
QuadroFXO will be transparent to Quadro IP PBX upon enabling the sharing mode.
•
Independent of the configuration on the QuadroFXO, the incoming calls on all shared FXO lines will be automatically routed to the
default Auto Attendant (00) once FXO sharing is activated. Occasionally, routed destinations can be then changed on Quadro IP PBX.
•
Any changes applied to the configuration of shared FXO lines on Quadro IP PBX will be automatically reflected in the FXO Settings
page and Call Routing table on the QuadroFXO device.
PSTN Lines Sharing page consists of the following
components:
The Provide PSTN lines for master device checkbox is used
to share the existing FXO lines to the remote Quadro.
Username and Password text fields are used to enter the
identification parameters for the authentication on the remote
Quadro IP PBX. In its turn, these authentication settings should
be added in the Authorization Parameters table on the master
Quadro IP PBX.
Master device IP text field requires the IP address of the
master Quadro current FXO lines will be shared for.
Master device port text field requires the port number of the
master Quadro current FXO lines will be shared for.
Registration State and Registration Date/Time fields indicate
read-only information about the last successful registration on
the master Quadro (i.e. when authentication was successful), its
state and the registration date/time.
Fig. II-96: PSTN Lines Sharing page
Please Note:
Any settings synchronization between the master and slave devices may take up to 60 seconds.