4.5
STORAGE & TRANSPORTATION
Equalizer tools should be stored in a cool dry place. Tools
should always be cleaned, serviced and lubricated prior to
storage. Ensure that tools are stored in their designated
packing cases.
4.6
OPERATING CONDITIONS
HYDRAULIC TOOLS:
Minimum Flange Contact Temperature: -30 °C (-22 °F)
Maximum Flange Contact Temperature: 70 °C (158 °F)
4.7
SUB-SEA USAGE
Using TFA12TE Sub-Sea
The TFA12TE is actuated by means of single-acting
spring-return hydraulic cylinder and can be used sub-sea
providing the following actions are taken:
• The gauge and manifold are removed from the
Equalizer HP hand-pump and the coupler is fitted
directly to the pump outlet (tools in this configuration
can be requested from Equalizer).
• The tool is connected to the Equalizer HP hand-pump
whilst still top-side.
• The pump release valve is fully opened and remains
open until the tool has descended to the working
depth. This will allow the pressure to equalise.
• The tool is actuated via the hand-pump by a diver.
• Upon completion of works the release valve is left in
the fully-open position until the tool has ascended to
the surface.
• The tool and pump are stripped-down, cleaned and
lubricated immediately to minimise corrosion.
Please note that a sub-sea TFA12TE tool cannot be
operated from top-side by use of a down-line. The return
springs in the hydraulic cylinders do not have sufficient
force to close the tool if used with a down-line from a
top-side pump, therefore the standard hydraulic tools will
not function correctly and may jam in place if used in this
configuration.