OPERATOR INSTRUCTION MANUAL
IM_TFA_12TE_Rev03_A4
TFA12TE
FLANGE ALIGNMENT TOOL
12
HYDRAULIC MANIFOLD OPERATION
Up to 4 TFA12TE tools can be manifolded to a single
HP1000S hydraulic Hand-Pump using the Equalizer
manifold.
Each tool can be independently isolated by closing the
corresponding valve. It is not recommended to isolate
or engage alignment tools while under load as an over-
load might occur. See the document ‘Use of Equalizer
International tools with a Hydraulic Manifold’ for further
guidance.
5.2
TFA12TE TOOL FUNCTION
HYDRAULIC TOOL OPERATION
The TFA12TE uses a hydraulic cylinder to advance the
Alignment Piston and align the flanges. The hydraulic
pressure is applied using an external hand pump, enabling
accurate control of the force applied. The maximum
working pressure of the tool is 510 bar (7400 psi).
HAND PUMP OPERATION
Consult the Instruction Manual for the Equalizer HP
Hand-Pump supplied in the kit. Only use the supplied
Hand-Pumps which have been regulated to 510 bar
(7400 psi) to suit this tool.
ACTUATING THE TFA12TE
Follow the Tool Operation instructions (see Section 3),
using the following instructions to actuate the TFA12TE
tool.
When the Hand-Pump release valve is closed, pumping
the Hand-Pump handle will advance the Alignment Piston.
When using multiple tools, ensure that the spread of all
tools correspond to keep the spreading force balanced.
RETRACTING THE TFA12TE
Opening the release valve will depressurise the cylinder
and cause it to retract under the force of its internal
spring. The handle does not need to be pumped to retract
the tool.
When using multiple tools, exercise caution while retracting
to keep the spreading force balanced as the gap is closed.