September 2011 Ed.2.0
EQUITEL – Technical Manual N968
50
System Event Log—Event Configuration
The checkboxes and pull-down menus are not available unless the
Syslog Client Mode
on the Syslog Configuration tab and the
E-mail Alert
on the SMTP Configuration tab are
enabled first.
This tab mainly controls whether an event notification is to be sent to the
Syslog
/
SMTP
server. The part of
System Event Selection
controls the event notification including
Device Cold Start and Authentication Failure. With the
Syslog
/
SMTP
checkbox ticked,
the event log/email alert will be sent to the system log server/SMTP server respectively.
As for the part of
Port Event Selection
, port events (link up, link down, and both) can be
sent to the system log server/SMTP server by setting the trigger condition for each port
respectively.
System event selection:
There are two event types—
Device Cold Start
and
Authentication Failure
.
Device Cold Start:
Tick the Syslog/SMTP checkboxes respectively to have the
system issue the event log/email alert to the system log/SMTP server when the
device executes the cold start action.
Authentication Failure:
When the SNMP authentication fails, the system will
issue the event log/email alert to the system log/SMTP server respectively.
Port event selection:
Each drop-down menu has four options—
Disable
,
Link UP
,
Link Down
, and
Link UP & Link Down
. Disable means no event will be sent to the
system log/SMTP server.
Link UP:
The system will issue a log message only when the link-up event of
the port occurs.
Link Down:
The system will issue a log message only when the link-down event
of port occurs.
Link UP & Link Down:
The system will issue a log message at the time when
port connection is link-up and link-down.
Summary of Contents for N968
Page 7: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 IPv6 Commands Set 148 ...
Page 19: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 12 Crossover Cable Schema ...
Page 25: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 18 ...
Page 54: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 47 Syslog Configuration interface ...
Page 56: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 49 SMTP Configuration interface ...
Page 58: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 51 Event Configuration interface ...
Page 65: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 58 IP Security interface ...
Page 68: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 61 Port Statistics interface ...
Page 70: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 63 Port Control interface ...
Page 79: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 72 State Activity of Switch 2 ...
Page 96: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 89 RSTP System Configuration interface ...
Page 98: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 91 RSTP Port Configuration interface ...
Page 100: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 93 SNMP System Configuration interface ...
Page 113: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 106 802 1x System Configuration interface ...
Page 117: ...September 2011 Ed 2 0 EQUITEL Technical Manual N968 110 Static MAC Addresses interface ...