Changing the oil
23
• Unscrew the spark plug with the spark
plug wrench supplied.
• Remove all traces of soot with a steel
wire brush. The electrodes should be a
tan colour.
• The gap between the electrodes
should be 0.7 – 0.8 mm. Adjust with a
screwdriver if necessary.
• Refit the spark carefully by hand to
avoid damaging the thread.
• Tighten with the spark plug spanner.
Do not over-tighten.
0.6 - 0.7 mm
Cleaning
• Keep all inlets and outlets clean and unobstructed.
• Use a damp cloth to wipe exterior surfaces.
• Use a soft brush to remove accumulated dirt or residue.
Storage and transport
• Allow the generator to cool down completely before storage.
• Turn the ON/OFF switch to the "OFF" position.
• Turn the fuel cap vent lever to the "OFF" position.
• Store or transport the generator upright in its normal operating position.
Long term storage
• Ensure the storage area is free of excess humidity and dust.
• Drain the fuel from the fuel tank into a suitable container.
• Turn the ON/OFF switch to the "ON" position and loosen the carburettor drain
screw. Drain the fuel from the carburettor into a suitable container.
• With the carburettor drain screw still open, remove the spark plug cap and pull
the ignition coil 3 - 4 times to drain the fuel from the fuel pump.
Summary of Contents for LGY20i
Page 1: ......
Page 27: ...EC Declaration of Conformity 27 EC Declaration of Conformity ...