ERBA GmbH
A-1230 Wien
Talpagasse 6
Servicehotline: Tel: +43(0) 1 930 10 - 160 · Fax: +43(0) 1 930 10 - 960 · E-Mail: service@erba.at
Instruction manual
17004 / 17015
Issue: 01/2017
Changes, print, punctuation and other errors reserved!
Page 23
GB - INSTRUCTION MANUAL
Condensed water
Condensed water can be drained using the drain valve (17) on the bottom of the tank (image 14).
The condensed water inside the tank contains oil and has to be disposed of accordingly.
Safety valve
The safety valve is set to the max. allowed tank pressure. It is forbidden to alter this valve in any way.
To ensure a perfect operation of the valve it has to be moved every now and then. Pull the ring untill
you hear the air venting from the valve. Then let go of the ring.
Check oil levels
The correct oil level is indicated on the oil gauge (4). It has to be between the red indicator and the
top of the gauge.
Oil replacement
Recommended oil:
SAE 15W/40
or similar. The first oil replacement should be done after 100
working hours. After that, the intervall is 500 working hours. Switch off the engine and disconnect
the power and vent any remaining pressure. Remove the screw from the oil drain (image J). Collect
the oil in a suitable container and avoid any oil spills. You may need to tilt the compressor slightly to
drain all the oil. Dispose of the oil in accordance with federal laws and regulations.
Once all oil has been drained screw the drain shut again. Fill fresh oil into the opening (12) until it
reaches the max. oil level (image K). Seal the opening with the oil plug (12).
Cleaning of the intake air filter
The filter needs to be cleaned every 300 working hours. Cogged air filters will significantly reduce
the power of the compressor. First remove the air filter from the compressor. Then unscrew the cap
of the filter and remove the sponge from inside the filterhousing. Shake or blow off (max. 3 bar) all
dust. Reassemble the filter and put it back on the compressor.
9. SERVICE AND REPLACEMENT PARTS