This menu allows to set:
The operating mode
The date
and then
the time (this order must be respected)
The timeout before its activation
The period of transmission of the Keep Alive frame
The period of transmission of frames in alert mode
The kind of transmission activated
The identifiers and the transmission modes depending on the communication technology available on the
product
o
For cellular : the IMEI number is the one of the EG-IoT internal module
o
For Sigfox, the Sigfox ID and the PACID can be read with the configuration application when
entering the character « i ».
o
For LoRa (use of OTAA connections) :
The DevEUI (8 digits : HWEUI of the embedded module)
The AppEUI (8 digits : 6572636F67656E65)
The AppKEY (16 digits : 4552434F47454E45522D454731313134).
These keys can be modified in the configuration menu.
For the tracking mode
o
The geofencing circular zone
o
The reference position
For the mode telemetering / pulse counting / Hour meter
o
The alert thresholds for high and low temperature
o
The modes of use of each digital input :
Pulse counting
Hour meter
Detection of status change
o
Alert threshold on each digital input
o
The initialization value of meters