6.1.3.3
Counting
Counting on upwards front
Counting on downwards front
≥12ms
≥12ms
≥ 50 ms
≥ 50 ms
Rest state = 0 / Low
Rest state = 1 / High
Ex :
1,0,125,0
Initialization of counter at 125, no alarm
Ex:
1,1,0,100
Alarm when the counter reaches 100
The alarm frame OpCode
17
is sent at the end of the
Keep Alive Time
.
6.1.3.4
Hour meter
Hour meter at high level
Hour meter at low level
Rest state = 0 / Low
Rest state = 1 / High
Ex :
2,0,0,0
Ex:
2,1,0,60
Alarm when the time reaches 60 mn.
The alarm frame OpCode
17
is sent at the end of the
Keep Alive Time
.
6.1.3.5
Front detection
Alarm on upwards front
Alarm on downwards front
60ms
60ms
Rest state = 0 / Low
Rest state = 1 / High
Ex :
3,0,0,0
Ex:
3,1,0,0
The alarm frame OpCode
17
is sent 60 ms after the change of status is taken into account.