6.1.3.6
Payload for Sigfox or LoRa
PayLoad
Op
Code
Compt.
1
Compt.
2
Res.
Res.
Res.
V
BAT
-
Temp.
°C
Status of inputs / Alarms
Bits
88
8
16
16
8
8
8
8
8
8
b7-b0
B15-b0
B15-b0
b7-b0
b7-b0
b7-b0
b7-b0
b7
B6-b0
b7
b6
b5
b4
b3
b2
b1
b0
Octet
11
0
1
2
3
4
5
6
7
8
9
10
Value
0x--
reserved
-
Status input 1
b0
11
Life frame of EG-IoT
17
Alarm frame
> +86 °C
0x7F
Status input 2
b1
FE
Service Init.
+86 °C
0x7E
0 °C
0x28
Counter 1 < Threshold
0
-40 °C
0x00
Counter
1 ≥ Threshold
1
Counter 2 < Threshold
0
Counter
2 ≥ Threshold
1
Tmp. °C > Low threshold
0
Tmp. °C ≤ Low threshold
1
Tmp. °C ≥ High
threshold
0
Tmp. °C < High
threshold
1
Compt.
Counter
Res.
Reserved
Reserved
b7
b6
Example of frame:
Opcode: Keep alive, Digital input 1 counter : 100 , Digital input 2 counter : 32, Vbat: 3.30V, T°int: 40°C
Frame :
(all values in
hexadecimal
)
Opcode ........................ : Keep alive
11
Digital input 1 counter .. : 100
0x
0064
Digital input 2 counter .. : 32
0x
0020
Reserved 1 & 2 ............ :
0x
00 0x00
Vbat .............................. : 3.30V (3.30 x 100)
– 200 = 130
0x
82
(Note : measure range 2.00V à 4.55V)
T°int .............................. : 40°C = 0x28, 0x28 + 0x29 (0°)
0x
51
(Note : measure range -40°C à 85°C)
Digital status ................ : none
0x
00
Frame in octets ............ :
0x11 0x00 0x64 0x00 0x20 0x00 0x00 0x82 0x51 0x00
Conversion in ASCII .... :
1100640020000000825100
Payload Sigfox/LoRa