EG-IoT_UG_demonstrator_006_UK
.docx
Page 29 / 34
Descriptions and non-contractual illustrations in this document are given as an indication only. ERCOGENER SAS reserves the right to make any
modifications. This document is the property of ERCOGENER SAS. It may not be reproduced or disclosed to a third party without the written
consent of ERCOGENER SAS.
6.1.3.8
Frame sent via TCP or UDP
SMS
Unit
Nb car
min.
Nb car
max.
Value
min.
Value
max.
Example
GSM IMEI/
Custom ID
-
0
15
-
-
123456789012345
Op code
-
2
2
11
FE
11
11
Life frame
Date
ddmm
yyyy
8
8
10012017
17
Alarm frame
Hour
hhmm
4
4
0000
2359
1221
FE
Service Init.
Counter 1
-
1
5
0
65535
47
Counter 2
-
1
5
0
65535
259
Alarm status
-
2
2
00
FF
02
b0
Status input 1
Reserved
-
1
1
0
0
0
b1
Status input 2
Reserved
-
1
1
0
0
0
b2
Alarm counter 1
V
BAT
mV
4
4
0
9999
3320
0
< Threshold
Temp.
°C
2
2
-40
+86
25
1
≥ Threshold
b3
Alarm counter 2
0
< Threshold
1
≥ Threshold
b4
Alarm low Temp.
0
< Threshold
1
≥ Threshold
b5
Alarm high Temp.
0
< Threshold
1
≥ Threshold
b6, b7
Reserved
Reserved
-
1
1
0
0
0
Status input 1
-
1
1
0
1
0
Status input 2
-
1
1
0
1
1
GSM RSSI level*
RSRQ (for LTE)*
-
1
3
0
31-99
34-255
12
GSM QUAL*
RSRO (for LTE)*
-
1
3
0
7-99
97-255
10
Number of character per
frame with separator
46
73
*
see ANNEX 3
– GSM (RSSI/QUAL) LTE (RSRQ/RSRP)
Example of frame:
ID : 1234564798012345
Opcode:11(Cyclic), Date: 25072017, Time: 1234, Counter value 1: 47, Counter value 2: 259, Counter status: 02, Reserved
:0, Reserved : 0; Vbat: 3.32V, T°int: 25.3°C,Analog status = 00, Input state1 =0, Input sate 2 = 1, RSSI=10, QUAL=10
FRAME
357520072362730,11,10012017,1221,47,249,02,0,0,3320,25,0,0,1,12,10
IMEI/ID Opcode
DATE
TIME
Counter
value
1
Counter
value
2
Counters
status
res.*
res.*
Vbat
T° int
Analog
status
Input
state 1
Input
state 2
GSM
RSSI
GSM
QUAL
Characters
69
15
2
8
4
5
5
2
5
5
4
5
1
1
1
3
3
Separators (,)
15
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
Total chars
84
res.* : reserved
TCP/UDP