EG-IoT_UG_demonstrator_006_UK
.docx
Page 30 / 34
Descriptions and non-contractual illustrations in this document are given as an indication only. ERCOGENER SAS reserves the right to make any
modifications. This document is the property of ERCOGENER SAS. It may not be reproduced or disclosed to a third party without the written
consent of ERCOGENER SAS.
7 Interface on M8 connector
Table 4 : Input E1/E2
Broche
Designation
8-wire cable
1
Input 1
White
5
GND
Grey
8
Input 2
Red
7.1
Contact input
Table 5 : Characteristics of opto-coupled inputs
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Current max.
I
F
Contact closed
33
µA
7.2
Opto-coupled input
Figure 3 : Opto-coupled input E1/E2
Table 6 : Characteristics of opto-coupled inputs
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Voltage max.
V
IN
± 30
V
DC
Current max.
I
F
à V
MAX
. ± 30V
DC
± 3.6
mA
Command voltage
V
ON
± 3.5
± 30
V
DC
Idle voltage
V
OFF
± 2
V
DC