EG_GenLoc354e_1040Q_UG_002_UK
Page 30 / 69
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
3.5.2
Option Multi 1- Wire Bus S0470C
This option
Multi 1-Wire
reference
S0470C
allows the reading of all 1-wire devices with the possibility to
have several devices on the same bus.
This option Multi 1-wire cannot be used with the
EaseLoc
application but can be directly
controlled with an
EGM
development.
Table 15 : Multi 1- Wire Bus description S0470C
14-pin connector
Signal
Pins N°
I/O
Kind of I/O
Description
Bus One Wire
GND
1
I/O
Analog
Bus Multi 1- Wire
8
Corresponds to wires
White/green
for One Wire Bus
Black
for GND
see ANNEX 2 - 14-pins Micro-FIT cable (Inputs/Outputs)
Table 16 : Multi 1- Wire Bus – Electrical characteristics S0470C
Characteristics
Symbols
Conditions
Min.
Typ. Max. Unit
Input Voltage – Low
V
IL
-0.3
0.9
V
DC
Input Voltage – High
V
IH
1.9
3.3
V
DC
Input Leakage Current
I
LEAK
-10
10
µA
DC
Input capacitance
C
IN
10
pF
Output Low-level Voltage
V
OL
@ charge 4mA
0.4
V
DC
Output High-level Voltage
V
OH
@ charge 4mA
2.8
3.3
V
DC
Active Pullup On Time
4, 5
t
APUOT
2.3
2.5 2.7
μ
s
Pulldown Slew Rate
6
)
P
DSRC
1
4.2
V/
μ
s
Pullup Slew Rate
6
)
P
USRC
0.8
4
V/
μ
s
Power-On Reset Trip Point
V
POR
2.2
V
Write-One/Read Low Time
t
W1L
7.6
8
8.4
μ
s
Read Sample Time
t
MSR
13.3 14
15
μ
s
1-Wire Time Slot
t
SLOT
65.8 69.3 72.8
μ
s
Fall Time High-to-Low
6, 7
t
F1
0.54
3.0
μ
s
Write-Zero Low Time
t
W0L
60
64
68
μ
s
Write-Zero Recovery Time
t
REC0
5.0
5.3 5.6
μ
s
Reset Low Time
t
RSTL
570
600 630
μ
s
Presence-Detect Sample Time
t
MSP
66.5 70
73.5
μ
s
Sampling for Short and Interrupt
t
SI
7.6
8
8.4
μ
s
Reset High Time
t
RSTH
554.8 584 613.2
μ
s
4
Active or resistive pullup choice is configurable.
5
Except for t
F1
, all 1-Wire timing specifications and t
APUOT
are derived from the same timing circuit.
Therefore, if one of these parameters is found to be off the typical value, it is safe to assume that all these
parameters deviate from their typical value in the same direction and by the same degree.
6
These values apply at full load, i.e., 1nF at standard speed and 0.3nF at overdrive speed. For reduced
load, the pulldown slew rate is slightly faster.
7
Fall time high-to-low (t
F1
) is derived from P
DSRC
, referenced from 2.97 V
DC
to 0.33 V
DC
.
Figure 9 : Internal electrical scheme of the Multi 1- Wire Bus S0470C
See Figure 8 : Internal electrical scheme of the One Wire bus
Summary of Contents for GenLoc 354e