5.1.3.2 With EGM standard library
The GenLoc 41e contains the EGM standard library; it is waiting for a command.
Connect the link RS232 between the DTE (COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
▪ Bits per second ..... :
115 200 bps
,
▪ Data Bits ................ :
8
,
▪ Parity ..................... :
None
,
▪ Stop Bits ................ :
1
,
▪ Flow control ........... :
material.
Use a communication software like Windows HyperTerminal ® .
Send the AT command. The modem returns OK. For more precision about the commands, see the
documents "EG_EGM_CL_xxx_yy" of ERCOGENER.
With this status, the two leds are off.
In the case where no communication can be established with the modem:
▪ Check the RS232 connection between the DTE and the modem (DCE),
▪ Check the configuration of the COM port of the DTE.
5.1.3.3 The application ERCOGENER EaseLoc-Vx
The GenLoc 41e contains the application EaseLoc_Vx.
Send the command ATI8. The modem returns the version (example of display)
EaseLoc V2.10b1 GenLoc41e-R40 eCos-Enabler IIIG_GSM0308-Thu Mar 17 10:29:40 2011
For more information about these AT commands and their associated parameters, see the documents
"Commands List EG_EaseLoc_Vx_CL_yyy_UK" of ERCOGENER.
5.1.3.4 The owner application
The GenLoc 41e contains your application.
Connect the RS232 link between the DTE (the COM port) and the modem (DCE).
Set the RS232 port of the DTE according to your parameters (speed, data bits, parity and stop bit).
Use a communication software like Windows HyperTerminal ®.
Check the display and the dialogue with the GenLoc 41e according to your own characteristics.