5.10 Turning off the modem
The modem contains the EGM standard library (see the documents "EG_EGM_CL_xxx_yy" of
ERCOGENER); in this case, it is strongly advised to un-register from the network with the command
AT+COPS=2.
There is no particular action to do on the GPS part before turning it.
If the Battery option is present, a mechanism allows to stop compeletely the application if the
external power supply is unplugged, and also to prepare the modem for storage or transport
phases in order to limit high discharges of the battery.
If the device is not used, it has to be deactivated by sending the following command:
If the modem contains an application developed with EGM
send the command
AT+GPIOSET=35,0
And cut the external power supply of the modem.
If the modem does not contain any embedded application,
via the Boot-Loader menu
Bootloader V4.03 GL41 UA Gener Ublox (HWE0 rev C)
GSM voltage = 4295 mV
1 - Update application
2 - Erase objects
M - GSM direct access
A - Advanced
P - Power off
E - Exit
Enter "P"
And cut the external power supply of the modem.
Important note
: The switching and the auto-maintain of the battery will be automatically
reactivated once the modem will be connected again to its external power
supply.
5.11 Updating procedure of the modem
To be able to benefit from the latest functions of the GenLoc 41e, an updating procedure can be used to
upgrade the software program in the modem.
This procedure consists in downloading the software into the internal Flash memory of the modem via the
RS232 link available on the 15-pin Sub HD connector.
Contact us for the software updating.