EG_GenLoc41e_1055_UG_003_UK
Page 39 / 71
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
7.2.2.5 Instruction and restrictions of use
The internal battery option is not cabled by default and its implementation must be made by us in our factory
(contact us).
When the battery is completely discharged, it takes around three hours to obtain a complete charge.
When the battery is connected and charged, the act of removing the power supply + VDC
does not turn off the equipment. For this see §
The battery cannot be replaced or modified by the user. The device must NOT be
opened. For any action on the battery: the device must be returned to factory.
Do not throw the modem and the battery on fire.
7.2.3 Protections of the power supply
The modem is protected by a fuse F2.5 A / L250 V or 2A / 32V directly assembled on the power supply cable
supplied with the modem.
The modem is also internally protected against voltage peaks of more than 32 V.
Filter guarantees:
following certification CE.
7.3 RS232 serial link
7.3.1 General Presentation
The RS232 interface provides an adaptation of the tension levels (V24/CMOS
V24/V28) between the
GSM/GPRS module (DCE) and the communication port of a PC (DTE).
The RS232 interface is internally protected (ESD protection) against electrostatic peaks coming from the
RS232.
Filter guarantees:
following certification CE.