7.5 BOOT
This signal must NOT be connected, NOT used. Its use is strictly reserved for the
manufacturer.
7.6 RESET
7.6.1 General presentation
This signal allows to make a Hardware RESET of the modem. In fact, this pin is used to force a RESET of
the modem, doing a low level during at least 10 ms.
This signal must be used only in case of emergency RESET.
This signal must be driven with an open collector assembly:
● pin 14 (RESET) at 0, for the modem Reset,
● pin 14 (RESET) at 1, for normal mode.
Pin description
This signal must be used only in case of emergency RESET. A Software RESET is always
preferable to a Hardware RESET. It is strongly unadvised to execute this function whilst in
communication or dialog, without having first detached it from the operator network.
Using the RESET does not restore the factory parameters.
For more information about the Software RESET, see the document "EG_EGM_CL_xxx_yy"
of ERCOGENER and see paragraph 5.10 and detach it correctly from the operator network.
7.6.2 RESET sequence
To activate the emergency RESET sequence, the RESET signal must be put to a low level during at least 10
ms.
As soon as the modem has been RESET, if a SIM card is inserted inside the SIM reader, you must wait for
the end of the initialization before accessing it again. Moreover, the acquisition time of a GPS position will
have to be taken into consideration.
Using the RESET does not restore the factory parameters.
Signal
Sub HD Connector
Pins number
I/O
I/O Type
Description
RESET
14
I/O
SCHMITT
Reset Modem