EG_GenLoc41e_1055_UG_003_UK
Page 58 / 71
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
8.2.4.3 Analog input - ANA1 (0 - 10V) on INPUT2
As an option, it is possible to have an analog input instead of the opto-coupled input I2.
This analog input allows to do a tension measure (contact us).
Table: Characteristics of the analog input option
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Analog input
ANA1
12
V
dc
Conversion range
6.5 V
≤ +V
DC
≤ 32V
0.010
10.33 V
dc
Polarization current
From 10 mV to 10.33 V
1.34
350
µA
dc
Resolution
10
bits
Internal electrical scheme of the option Analog Input 1
The integrator has the responsibility to protect the input from electric disturbances and to
respect the values of the functioning parameters.
8.2.4.4 Analog Input - ANA2 (0 - 10V) on SPKN
As an option, it is possible to have an analog input instead of the SPKN output.
This analog input allows to do a tension measure.
If the ANA2 option is present, the audio speaker output is available between SPKP (pin 10 of
the 15-pin sub D HD) and the 0V.
In this case, the audio power available is divided by 2 compared with the specifications.
Table: Characteristics of the analog input option
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Analog input
ANA2
12
V
dc
Conversion range
6
.5 V ≤ +V
DC
≤ 32V
0.010
10.33 V
dc
Polarization current
De 10 mV à 10.33 V
1.34
350
µA
dc
Resolution
10
bits