Internal electrical scheme of the option Analog Input 2
The integrator has the responsibility to protect the input from electric disturbances and to
respect the values of the functioning parameters.
8.2.4.5 Input/Output (0
– 3.3 V) direct on INPUT2, INPUT3
As an option on the GenLoc 41e, it is possible to have 3.3V input directly connected to the ARM. (Contact
us).
These Input/Output INPUT2, INPUT3 are directly connected on the ARM : INPUT2 on Port
PA1 and INPUT3 on port PA2.
The selection of the direction (Input/Output) is done by software.
Table: Electric characteristics of the ARM
Internal electric scheme of the option direct Input/Output
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Input Voltage
– Low
V
IL
-0.3
0.8
V
dc
Input Voltage
– High
V
IH
2
3.5
V
dc
Hysteresis Voltage
V
Hys
0.4
0.7
V
dc
Input Leakage Current
I
LEAK
-4
38
µA
dc
Input capacitance
C
IN
14
pF
Output Low-level Voltage
V
OL
0.4
V
dc
Output High-level Voltage
V
OH
2.8
V
dc
Output Current
I
o
±16
mA
DC