8.2.4.2
Open collector
output (O1)
Table: Characteristics of the open-collector output
Characteristics
Symbols
Conditions
Max.
Unit
max. tension
V
CE0
Transmitter open
48
V
DC
max. tension
V
CES
V
BE
= 0 V
48
V
DC
Collector current
I
C
0.5
A
Saturation voltage
V
CEsat
I
C
= 500 mA
1.3
V
Dissipation
P
Ttot
T
amb
≤ 25 °C, T
j
= 110 °C
0.78
W
Electric scheme of the output