D2 Series
User Guide, Rev. 00 (Feb 2015)
17
Baud Rate Radio [2,400/3,600/4,800] (bps)
: To select the Radio link data speed. Choose the
4,800
bps
only
for high SINAD networks, e.g. with aerials in optical view and adequately high on the earth
surface.
Parity [N,E,O]
: Permits the
Parity Bit
utilisation in
Odd (O)
mode or in
Even (E)
mode. If
N (No
parity)
is selected the message frame must contain only 8 bits.
Digital IN Repetition Time [1..60] (minutes)
: To set the repetition time interval between two
successive refreshes of the
Digital input status
. The value
0
inhibit the periodic refresh but, in all
cases, this status is sent at every change of the digital input and/or at every data transmission with
the exception of the
Broadcasting Mode
.
Advanced configuration
Its Addr [1..255]
: It is the address of the unit. In a
point
-
multipoint network
the
Master
unit
must
have
Its Address = 1
.
Target [1..255]
: The address of the destination radiomodem. In the
Broadcasting Mode
the
inserted value is not considered while in the
Address from DTE Mode
it is furnished by the DTE. A
valid value
must be
inserted in this field independently from the utilisation mode.
Digip. [0..255]
: The address of the unit used as
repeater
. If a network don't contain a repeater, the
value in this field
must be set to 0
.