SR2 Technical Manual EN
Indice : C
25/03/2019
Firmware v2.9
4 / 31
ERECA SAS - 75 rue d'Orgemont, 95210 St Gratien France
T : +33 1 39 89 76 23 W : www.ereca.fr
1.4 OPTIONS
Numerous hardware options can be fitted in the Stage Racer 2:
•
8 switchable mic/line gain blocks with phantom power injection and gain management,
•
Dante module providing 64 I/O channels of Dante / AES67 (shared with Ethernet port 1),
•
6 additional 500Kbs RS422 serial channels,
•
10-16VDC input to connect an external battery used in case of mains power loss,
•
Extended range QSFP+ for up to 40km transmission.
1.5 VISUALISATION
The equipment has multiple front-facing LED for signal presence and alarm display as well an Oled screen
for visualisation of IP address, trunk occupancy and optical power.
1.6 SETUP
Each frame runs an internal web server to enable remote management and setup of the entire network or
individual machine. The web interface can be accessed via the admin port of any machine from any device.
1.7 POWER
Each equipment has a built in redundant Mains power supply and can optionally be equipped with a DC
input compatible with batteries used for Cameras. Battery energy will be drawn only if both mains sources
are down, when mains will reappear battery current draw stops.