ERECA, 75 rue d'Orgemont, 95210 Saint Gratien, France T: +33 1 39 89 76 23
SR2 Installation Manual EN
Indice : C
06/01/2020
15 / 19
1.4.6 AUDIO
AES/MADI led state depends of the equipment setting (4 AES
or
2 AES + MADI IN + MADI OUT).
4 bidirectional AES signals.
•
AES 1-4, Green LED ON,
when a 48Khz AES signal is fed on the corresponding port
In that case,
All Madi Led are Off.
2 bidirectional AES s 1 MADI I/O
•
AES 1-2 Green LED ON,
when a 48KHz AES signal is fed on the corresponding port
•
MADI IN, Green LED ON
, when a MADI signal is received on MADI In Port
•
MADI OUT, Green LED ON
, when a MADI signal is sent on MADI Out Port
•
MADI UNS., Red LED ON
, if the internal reclocker is not locked on the input MADI signal.
Dante
•
Dante, Green LED ON
, when the Dante hardware module is properly installed and recognised by the
external Dante controller.
Analog Audio
•
1-16, Green LED ON,
indicates the activity of an analog audio signal received on the input port and/or
the output port.
Note: The trigger level is set to -10dBm approximatively. Audio activity LEDs are refreshed every
500ms displaying if there was a level > -10dBm on the past 500ms period providing a smooth display.
1.4.7 GPIO
•
GPIO 1-8, Green LED ON
, when a GPI or GPO is activated on their respective input
and output.