4. Maintenance 

4.1 Cleaning 

The chair should be cleaned using soap and warm water after use. The seat may be removed 
and  washed  down.  If  the  chair  is  used  for  more  than  one  person  MUST  be  thoroughly 
cleaned. 

When the chair is used as a toilet chair ensure that the bucket is  correctly placed under the 
seat.  The  bucket  and  lid  must  be  used  and  cleaned  according  to  relevant  regulations.  The 

bucket and lid can stand cleaning in a bedpan washer

.

 

4.2 Storage 

The chair must be stored in a dry environment with relative humidity under 90%. 

5. Check 

The  chair  must  be  serviced  and  thoroughly  checked  at  least  twice  a  year  by  qualified  and 
authorised personnel. 
 
It is the onus of the buyer to ensure that this annual check is carried out. 
 
If  it  is  necessary  to  replace  any  parts  due  to  wear  or  damage  these  must  be 
obtained/purchased from Ergolet. 

6. Technical data 

 

Hera II/140   

Hera II maxi/250 

Seat width 

430 mm 

 

545 mm 

Distance between arm rests 

480 mm 

 

610 mm 

Seat depth 

420 mm 

 

445 mm 

Seat height 

530-610 mm   

545-625 mm 

Total width 

600 mm 

 

735 mm 

Total height (top of handles) 

1035-1115 mm  

1080-1180 mm 

Angle of tilt 

+5° to -30° 

 

+5° to -30° 

Weight of the chair 

22 kg 

 

24 kg 

Weight capacity (SWL) 

140 kg 

 

250 kg

 

 

Summary of Contents for Hera II Maxi/250

Page 1: ...portant information This Manual must be read before the product is used This manual is intended for technicians installers therapists and other personnel in connection with the use servicing and maint...

Page 2: ...2...

Page 3: ...packing 6 1 6 Transport 6 2 Assembly instruction 7 3 Use and adjustment 3 1 Using the Hera II 7 3 2 Using the tilt function 7 3 3 Adjusting the Hera II 8 4 Maintenance 4 1 Cleaning 9 4 2 Storage 9 5 C...

Page 4: ...iminated Hera II is intended for indoor use under normal temperatures 20 40 C and relative humidity 40 90 1 2 Safety instructions This user instruction must be read thoroughly before the Hera II is ta...

Page 5: ...arer is responsible for ensuring that a daily check is carried out BEFORE Hera II is used including the following 1 Ensure that there are no parts missing 2 Check that there are no signs of rust wear...

Page 6: ...product is to be used on other sites or for return shipment in case of repair 1 6 Transport The Hera II is most safely transported using the original packing Symbols are printed on the packaging to en...

Page 7: ...he Hera II The Hera II chair is normally used in the following situations 1 When washing in the bathroom under the shower or by the bath 2 When transporting the user to the bathroom 3 For other purpos...

Page 8: ...automatically angle itself according to the pressure of the user It can also be moved up or down to suit individual needs 1 Loosen the screws on the brackets placing the unit at the correct height an...

Page 9: ...ironment with relative humidity under 90 5 Check The chair must be serviced and thoroughly checked at least twice a year by qualified and authorised personnel It is the onus of the buyer to ensure tha...

Page 10: ...d in an environmentally correct way either through reuse or recycling 7 2 Quality Ergolet is certified according to the quality standard ISO 9001 and ISO 13485 These certifications mean that the produ...

Page 11: ...forward backrest Hera II Maxi Seat lid 047 00250 047 00255 047 00260 047 00261 047 00550 PU seat Seat with hygiene opening Lid for PU seat Lid for hygiene opening Gel cushion Foot leg support 047 0003...

Page 12: ...12 Phone 45 70 27 37 20 Fax 45 70 27 37 19 Email ergolet ergolet dk www ergolet com Manufacturer Ergolet Taarnborgvej 12 C 4220 Korsoer Denmark 9 3 4 2 E F C L A S S I E N I S O 1 0 5 3 5 910 00765UK...

Reviews: