6.2 Dimensions 

1.

 

Highest point 

2.

 

Maximum reach point 

3.

 

Lowest position 

 

a) Max. height of CSP*  

1980 mm (75 in) 

b) Min. Height of CSP* 

680 mm (27 in) 

c) Lifting range 

 

1300 mm (51 in) 

 

d) Min. Dist. from wall to CSP*  

at max. height (legs spread):     530 mm (21 in) 

 

e) Min. Dist. from wall to CSP* 

at max. reach (legs spread): 

180 mm (7 in) 

 

f) Min. Dist. from wall to CSP* 

  at min. height (legs spread): 360 mm (14 in) 

 

g) Max. reach at 600 mm  

  (reference height):580 mm (23 in) 

 

h) Max. reach from base 

600 mm (24 in) 

 

i) Reach from base with 

  legs spread to 700 mm 

180 mm (7 in) 

 

j) Base height 

120 mm (5 in) 

 

k) Floor to baseplate 

50 mm (2 in) 

 

l) Min. internal width 

550 mm (22 in) 

 

m) Max. internal width 

920 mm (36 in) 

 

n) Internal width at max reach 890 mm (35 in) 

 

Turning diameter 

1430 mm (56 in) 

* Central suspensions point 

 

Weight: 

Weight in total: 

45.2 kg (99.6 Ib) 

Mast incl. battery:  20.4 kg (Battery 2.8 kg) (6.2 Ib) 

Base/legs: 

24.8 kg (54.7 Ib)   

Note:

 Total weight is without spreader bar. 

 

 

Summary of Contents for Solar/185

Page 1: ...on Important information This user instruction must be read before the Solar 185 is used This user instruction is intended for technicians installers therapists and other personnel in connection with...

Page 2: ...2...

Page 3: ...3 Safety functions 11 2 4 Charging 12 2 5 Transport 13 3 Use 13 3 1 Using the Solar 13 3 2 Using the control box 13 4 Maintenance 14 4 1 Cleaning 14 4 2 Storage 14 4 3 Special environments 14 5 Check...

Page 4: ...cific information about which models can be used The Solar is intended for indoor use under normal temperatures 2 C to 40 C 36 F to 104 F and relative humidity 40 90 1 2 Safety instructions Important...

Page 5: ...d the hand control If the checks or the use of the Solar generate unusual noises then the Solar must not be used before a qualified technician has carried out a safety check on the Solar Check the lif...

Page 6: ...pair or annual check Content of the box 1 Base with legs and leg spreading 2 Mast with actuator and lifting arm 3 Spreader bar 4 Hand control 5 Control box 6 Handles 7 Battery 8 Tools Allen key spanne...

Page 7: ...the bolt nut Fig 1 6D Put the cap on the nut Fig 1 6D 4 Assembly the handles on the mast with two screws and tighten with the Allen key Fig 1 6E Fig 1 6E 5 The hand control lifting arm and electrical...

Page 8: ...ox Fig 1 6G 7 Attach the spreader bar Rotate the attachment point so it is pointing upwards insert the spreader bar and rotate 90 clockwise while pressing down firmly Fig 1 6H Note A firm press must b...

Page 9: ...der bar Winncare Nordic accepts no responsibility if slings are attached incorrectly it is always the onus of the carer helper to ensure that the sling is correct for the situation needs and is correc...

Page 10: ...Connecting plug electrical leg spreading 4 Connecting plug power supply 5 ON indicates that main supply is on 6 Charge indicates charging on the battery see section 2 4 7 Lift up down The up down func...

Page 11: ...reading Press and the leg spreading moves together Press and the leg spreading will spread outwards 2 3 Safety functions Emergency stop This function is only to be used in an emergency e g if the Sola...

Page 12: ...ere are 3 symbols on the hand control which indicate the power level in the battery Battery 25 An audible battery alarm will alert when there is a 25 capacity remaining in the battery Battery 50 Recom...

Page 13: ...e counters Battery state Overload information Service visit reports To access this information a readout tool is required This service data tool can be purchased from Winncare Nordic or your local dea...

Page 14: ...lease contact your local dealer or Winncare Nordic 5 CHECK SERVICE DATA AND TROUBLESHOOTING 5 1 Annual check The manufacturer Winncare Nordic stipulates that a qualified and authorised person MUST che...

Page 15: ...Release the emergency stop see section 2 3 Possible cause Defect hand control Solution Try using another hand control Alternative is to get a new hand control from the dealer Possible cause Flat batte...

Page 16: ...ty cycle 10 max 2 min 18 min Manually emergency lowering Yes Electronically lowering Yes Electrical details Power supply Input 100 240 VAC 50 60 Hz max 0 4 A Output voltage 24V Control box Output 250...

Page 17: ...gs spread 360 mm 14 in g Max reach at 600 mm reference height 580 mm 23 in h Max reach from base 600 mm 24 in i Reach from base with legs spread to 700 mm 180 mm 7 in j Base height 120 mm 5 in k Floor...

Page 18: ...nvironment if not handled in an environmentally responsible way 7 2 Battery The Solar is equipped with one battery which may be returned either to the local recycling station or to Winncare Nordic at...

Page 19: ...r bar 2 points 48 cm spreader bar 3 points spreader bar Spreader bars with weigh scale 017 00117 017 00144 017 00143 2 points 58 cm spreader bar with weigh scale 2 points 48 cm spreader bar with weigh...

Page 20: ...3 4 2 E F C L A S S I E N I S O 1 0 5 3 5 Phone 45 70 27 37 20 Fax 45 70 27 37 19 Email Info winncare dk www winncare com Manufacturer Winncare Nordic ApS Taarnborgvej 12 C 4220 Korsoer Denmark 910 00...

Reviews: