Maintenance
23
1
2
3
4
5
6
7
8
9
10
11
4 Maintenance
4.1 Maintenance
intervals
clean
in operating hours (oh)
1)
all
replace
as
requd
daily²
)
200 500 800 1.600 3.000 5.000 10.000
40.000
action
refer to section
part number
/
filter mats (two-part)
front panel
4.5.1
85533 (2x)
/
filter mat
canopy
4.5.2
84156 (1x)
Ergoline SD power 25 W
UV low pressure lamp 4.4.1/4.4.2/4.4.3 11122
starter
4)
UV low pressure lamp 4.4.1/4.4.2/4.4.3 10047
Ergoline SR turbo power
6)
UV low pressure lamp 4.4.1/4.4.2/4.4.3 10855
Ergoline R plus turbo power
7)
UV low pressure lamp 4.4.1/4.4.2/4.4.3 11494
starter
4)
UV low pressure lamp 4.4.1/4.4.2/4.4.3 10002
decorative lighting
low pressure lamp
4.4.4
11122
starter
4)
decorative
lighting
4.4.4
10047
acrylic panel (sunbed base)
4.2
86004
acrylic panel (intermediate)
4.2
-
plastic parts
4.2
-
sieve cylinder
air conditioning system 4.6.2
34967
lamellas
air conditioning system 4.6.2
-
fan
3)
circulating air
7
76817
fan
3)
outlet air
7
11595
steel wire
3)
lifting
mechanism
7
51320
draw spring
3)
7
51241
draw spring
3)
fall
protection
7
51335
1)
The specified maintenance intervals are maximum values. Shorter maintenance intervals may be
necessary depending upon the circumstances.
2)
Every day or after every use.
3)
A minimum of every 5 years by after-sales service
4)
We recommend that the starters also be replaced when the UV low-pressure lamps and low
pressure lamps are replaced.
5)
Depending on the extent of soiling or wear
6)
UV type 4
7)
UV type 3
Summary of Contents for Classik 475
Page 2: ...Ergoline Pro Sunbed from the No 1 2 ...
Page 8: ...8 ...
Page 14: ...General 14 1 2 3 4 5 6 7 8 9 10 11 ...
Page 36: ...Maintenance 36 1 2 3 4 5 6 7 8 9 10 11 ...
Page 40: ...Fault cause and remedy 40 1 2 3 4 5 6 7 8 9 10 11 ...
Page 44: ...Technical data 44 1 2 3 4 5 6 7 8 9 10 11 ...
Page 46: ...After sales service 46 1 2 3 4 5 6 7 8 9 10 11 ...
Page 50: ...Warranty EU Conformity 50 1 2 3 4 5 6 7 8 9 10 11 ...
Page 53: ......